StayCurrentMD · Rigid Bronchoscopy for Diagnosis and Treatment of Proximal Pouch Fistula in...
Follow
Video4 min·Published Feb 2020Older

Rigid Bronchoscopy for Diagnosis and Treatment of Proximal Pouch Fistula in...

Chapter 1 of 1 · Case-Based Learning

Proximal fistula case

Missed Proximal Tracheoesophageal Fistula: Case Presentation and Endoscopic Management Attempt

Try
Intelligent Search· scoped to esophageal atresia · not medical adviceSearch the whole library →
What the experts said0 expert statements · 12 host summaries
Proximal fistulas in esophageal atresia can be missed even when rigid bronchoscopy is performed routinely prior to repair of presumed type C esophageal atresia with distal tracheoesophageal fistula.
Host summaryThe host summarizing a resource · not cited in answers
Proximal tracheoesophageal fistulas are often subtle and look quite different from distal fistulas.
Host summaryThe host summarizing a resource · not cited in answers
The distal fistula in this case was located 1.5 to 2 centimeters proximal to the carina on initial rigid bronchoscopy.
Host summaryThe host summarizing a resource · not cited in answers
A routine esophagogram performed 6 days after repair showed a tracheoesophageal fistula despite the absence of a leak or significant stenosis.
Host summaryThe host summarizing a resource · not cited in answers
Rigid bronchoscopy to evaluate for missed proximal fistula was performed a week after initial repair to minimize the chances of traumatizing the recently ligated fistula.
Host summaryThe host summarizing a resource · not cited in answers
The proximal fistula appeared as a subtle fold approximately 1 centimeter proximal to the distal fistula site on bronchoscopy.
Host summaryThe host summarizing a resource · not cited in answers
A thin suction catheter could not be passed through the proximal fistula fold, but a glide wire was easily passed, confirming the presence of a proximal fistula.
Host summaryThe host summarizing a resource · not cited in answers
Endoscopic treatment involved using a glide wire to stent the fistula open while cauterizing the tract with bugby cautery until the tract and fistula wall were fully cauterized.
Host summaryThe host summarizing a resource · not cited in answers
Following cauterization, Deflux (dextranomer hyaluronic acid copolymer) was injected into the fistula tract.
Host summaryThe host summarizing a resource · not cited in answers
The endoscopic procedure was unsuccessful, and the proximal fistula remained patent on esophagogram two weeks later.
Host summaryThe host summarizing a resource · not cited in answers
The patient subsequently underwent successful repair of the proximal fistula through a right neck incision.
Host summaryThe host summarizing a resource · not cited in answers
If any suspicion of proximal fistula is seen on rigid bronchoscopy, insufflation of air through the esophageal pouch or installation of methylene blue may help confirm a proximal fistula.
Host summaryThe host summarizing a resource · not cited in answers