Article

Combined laparoscopic-fluoroscopic technique for primary gastrojejunostomy button tube placement

Published: Reading: 1 min

Abstract

Abstract

Background

Gastrojejunostomy (GJ) tubes are frequently used to provide pediatric enteral nutritional support for pediatric patients. Various placement methods have been described, each with attendant advantages and disadvantages.

Description of the operative technique

We present a technique for primary laparoscopic/fluoroscopic GJ button tube placement designed to avoid delay in placement of the jejunal limb, and difficulties associated with endoscopic-assisted and primary fluoroscopic placement.

Results

There were 52 gastrojejunostomy button tubes placed via this technique in patients ranging from 3.8 to 90.3 kg in weight. Three postoperative complications were identified; one bowel perforation on postoperative day two, and two tube dislodgements within 30 days.

Conclusion

The described technique was uniformly effective and was associated with a low complication rate (5.8%).

Keywords

Hashtags

This article is published on an external journal. Click below to read the full text.

Read full article ↗
How to cite: GlobalCastMD. Combined laparoscopic-fluoroscopic technique for primary gastrojejunostomy button tube placement. GlobalCastMD Medical Library. 2018-12-21. https://origin-library.globalcastmd.com/article/835?via_space=dr-todd-ponsky

Comments (0)